News
EPA Verification
EPA Program Verifies TraceDetect’s Automated Arsenic Analyzer
Award
TraceDetect Wins "New Technology" Award for Automated Arsenic Analyzer
Events
Feb. 20-22, 2008
SCMA – South Central Membrane Association
El Paso, TX
March 3-6, 2008
Pittcon 2008 Conference & Expo, Booth 2312
New Orleans, LA
March 29 – April 1, 2008
South Carolina Environmental Conference 2008 – AWWA, Booth 130
Myrtle Beach, SC
May 20-22, 2008
EPA Science Forum 2008 Innovative Technologies – Key to Environmental and Economic Progress
Washington, DC
June 8-11, 2008
ACE08 – AWWA Annual Conference & Exposition, Booth 741
Atlanta, GA
July 14-17, 2008
AMTA/SEDA 2008 Joint Conference & Exposition – Membrane Week, Booth 307
Naples, FL
Sept. 22-24, 2008
MINExpo International 2008, Booth #4910
Las Vegas, NV
Oct. 19-22, 2008
WEFTEC.08 – Annual Technical Conference & Exhibition, Booth 13039
Chicago, IL
Oct. 20-23, 2008
CA-NV AWWA – Annual Fall Conference 2008
Reno, NV
Nov. 11-12, 2008
Ultra Pure Water Conference – Microelectronics Water
Phoenix, AZ
Nov. 16-20, 2008
WQTC – AWWA Water Quality Technology Conference & Exposition
Cincinnati, OH
Explorer Software - Calibration
The calibration capability of the software has been extensively upgraded. In particular, you no longer loose a calibration (and a half-hour of work) if you make a numerical data entry error during calibration.
- A Calibration Setup-Wizard is now used to setup the calibration mode, the standards, the and dilutions associated with the calibration.
- Each calibration addition now consists of 0 - 5 "pre-scans" that are made and discarded, and 1 - 4 "measurement-scans" that are averaged together prior to peak-finding and inclusion into the calibration data set.
- Manual edits to the baseline(s) of the averaged calibration scans can be performed as the calibration proceeds or after the calibration is finished.
- The calibration Summary has been grouped into a single tabbed dialog showing the calibration calculation and graph, the additions, the dilutions and starting volume and the peak-data.
- The starting volume can be edited after the calibration has been finished.
- The additions made during the calibration can be edited after the calibration has been finished.
- The concentration of the standards used can be edited after the calibration has been finished.
- Any of the calibration data points can be omitted from the calibration best-fit calculation (on a scan-by-scan basis) after the calibration has been finished. Omitted points are still displayed on the calibration curve.
- The calibration routine now supports calibrations using standards that consist of mixtures of metals.
- The calibration routine no longer requires that the metals to be calibrated display a peak for that metal in the first calibration scan.
- We now associate with each calibration a complete dilution/concentration calculation.
- The new Calibration Summary Page shows results of the calibration or MSN measurement.
Contact us for more information, pricing, and availability.