News
EPA Verification
EPA Program Verifies TraceDetect’s Automated Arsenic Analyzer
Award
TraceDetect Wins "New Technology" Award for Automated Arsenic Analyzer
Events
Feb. 20-22, 2008
SCMA – South Central Membrane Association
El Paso, TX
March 3-6, 2008
Pittcon 2008 Conference & Expo, Booth 2312
New Orleans, LA
March 29 – April 1, 2008
South Carolina Environmental Conference 2008 – AWWA, Booth 130
Myrtle Beach, SC
May 20-22, 2008
EPA Science Forum 2008 Innovative Technologies – Key to Environmental and Economic Progress
Washington, DC
June 8-11, 2008
ACE08 – AWWA Annual Conference & Exposition, Booth 741
Atlanta, GA
July 14-17, 2008
AMTA/SEDA 2008 Joint Conference & Exposition – Membrane Week, Booth 307
Naples, FL
Sept. 22-24, 2008
MINExpo International 2008, Booth #4910
Las Vegas, NV
Oct. 19-22, 2008
WEFTEC.08 – Annual Technical Conference & Exhibition, Booth 13039
Chicago, IL
Oct. 20-23, 2008
CA-NV AWWA – Annual Fall Conference 2008
Reno, NV
Nov. 11-12, 2008
Ultra Pure Water Conference – Microelectronics Water
Phoenix, AZ
Nov. 16-20, 2008
WQTC – AWWA Water Quality Technology Conference & Exposition
Cincinnati, OH

Nano-Band™ Explorer II
Now, metals testing onsite, under your control, and ready to grab-and-go!
Offering the same great versatility and accuracy as our original Nano-Band Explorer Benchtop system, the Explorer II offers simplified measurements and comes in a lightweight, sturdy briefcase perfect for the lab or field. In just minutes, the Explorer II measures trace metals in aqueous solutions, at sub-ppb detection levels.
Our advanced TriTrode™ electrode technology is forging new territory for our Nano-Band Explorer II system. The new all-in-one TriTrode electrode unites all three system electrodes into one convenient piece. Combining the Nano-Band working electrode, reference electrode, and auxiliary electrode into one, the TriTrode offers easier setup, higher reliability, and simple maintenance.
The Nano-Band Explorer II is the perfect tool for research & manufacturing applications:
- Manual operation allows ultimate flexibility when measuring unique samples
- Laboratory benchtop measurements are quick & easy
- Perform measurements on the plant floor or at remediation sites with the Explorer II in its lightweight, field-portable briefcase
Explorer II Features
- Rapid & accurate results
- Excellent correlation with ICP-MS (+/- 10% typical)
- TriTrode electrode technology
- Reduces electrode cabling to a single cable connection for quick setup & easy operation
- Single connection provides higher reliability
- Simple electrode cleaning and maintenance
- Multiple measurement techniques are supported: stripping voltammetry (ASV & CSV), cyclic voltammetry, amperometric measurements, pH, ORP, and ISE.
- Powerful, user-friendly, Windows-based analytical software
- Report generation capability

